Suomeksi

 

QUALITY SYSTEM

We are serving our clients doing high quality work performance according to existing standards and requirements. We base our business on client service and quality thinking.

We are doing heat treatment works according to client's instructions following ISO9000 quality system.


Work instructions are based on the standard SFS-5863 "Guidelines for quality requirements for heat treatment in connection with welding and allied processes".
This standard is use in EU as a quality report.

Each heat treatment work is documented as a heat treatment certificate that is an official document of the work. If the size of the project requires it is possible to deliver documents as paperless version on a CD.

Uniform temperature of a furnace

The uniformity of the furnaces is checked by regular performed measurements of uniform temperature. This is done each 36 moths or after each reparation work.

Zone heat treatment

The size of the object or possibility for transport can set limits for heat treatment in furnace. Then the heat treatment is done as a local zone heat treatment. We have the latest technology and facilities in use for high quality on site heat treatments.

Calibration

Our heat treatment devices are calibrated with instruments, which are tested in official testing laboratory.

 

Intervals of calibration

Device
Interval
[months]
Regulators of furnaces
6 ± 1
Temperature registration devices
6 ± 1
Mobile heat treatment units
6 ± 1


Minimum number of measurement points in local heat treatment of pipes

Outside diameter of pipe Number of measuring points Pitch
[mm] [pieces] [°]
… 170 1 -
171 … 370 2 180
371 … 550 3 120
550 … 4 90